It can be a lot more important to get an interior air barrier than an interior vapor retarder. Make certain that you have got established a very good air barrier by sealing all penetrations and cracks.

Even so, two other areas of aspect-roof have already been dry walled more than with fiberglass as well as a plastic sheet -- the bathroom closet as well as the hallway. I am scared to check with but need to I open These up yet again?

Your plan to install a stack of rigid foam rectangles in Every single rafter bay is known as the "Slash-and-cobble" way of insulation. It's a technique typically chosen by homeowners, but in no way selected by insulation contractors.

Excellent short article and discussion. I have a matter about an existing unvented attic assembly. The rafters are 2x4's and also the bays between them are wholly filled with closed cell spray foam. I would like to include two 1in layers of polyiso in the direction of the inside of attic after which cover with a vapor open up membrane to airseal the assembly.

If you're a GBA member, you now know that GBA has many architectural specifics in its element library for you to review and down load.

Thanks for the comments. We won't ever A/C the making (It'll be solar powered). The wind is really continuous, but it is a humid environment, so humidity Manage is absolutely on my thoughts.

According to section R806.3 in the 2006 Worldwide Residential Code (IRC), “A minimum of a one-inch Room shall be delivered between the insulation plus the roof sheathing and for the location of the vent.” This kind of vent Area is often created by setting up 1 inch by one inch “sticks” from the upper corners of every rafter bay, followed by rigid cardboard, slim plywood, OSB, fiberboard sheathing, or panels of rigid foam insulation.

In addition to asking you viewers for a review of my plan, I've Yet another query introduced about by fears expressed by a local builder. He is anxious that once the AC ducts are Within the conditioned Room that the ducts might be prone to sweat and will drip all over my furnishings.

My feeling is that the dew issue profile would wind up in the XPS foam board, therefore a VB should be put on initial deck. So as of assembly:

I have a partial cathedral ceiling during the completed attic of my household in zone 4 (TN). Each individual slope in the roof is split approximately in thirds by 3 diverse scenarios: knee partitions with the outer thirds, "cathedral" ceiling in the center thirds, along with a vented "attic" in the center third with a ridge vent - a standard scenario with completed attics, at least around here. I've a big dilemma in the summertime with overheating. The insulation isn't really Performing basics effectively since it was inadequately insulated with just R-19 fiberglass batts amongst the rafters without a air flow baffle or ample soffit venting and only r-19 blown to the "attic Area". Furthermore, my upstairs HVAC ducts are operate while site here in the actually hot "attic" Room under the ridge. Based on what i haved figured out from a number of articles below, my planned Alternative will be to cathedralize the complete roof, eave to ridge: put in continous air-restricted internet site-created 2" vent channels using foil-confronted polyiso board (as recommended in ), setting up steady soffit vents to greatly improve the airflow from soffit to ridge, building an air-limited ceiling beneath the rafters, and, most importantly, convey the ductwork In the conditioned envelope.

I really need to wonder When the failure from the Image would have occured if the hip and ridge was vented and anything else exactly the same?

At last (I promise This can be my past matter). With regards to my fiberglass batts: Will the experiencing that comes with it retard the drying out process that I described higher than (does it issue what facet I set it on within the purlin cavity?

If a building inspector insists that you put in some sort of interior “vapor barrier,” you may always install a sensible vapor retarder like MemBrain to fulfill your inspector.

The sides with the roof are lined with asphalt shingled (GAF Slateline to be precise). It appears like I should pull down go to these guys the fiberglass and possess it spray-foamed before I drywall.