Q. "I are using rigid breadboard fashion expanded polystyrene from the rim joists and thought the same can be put beneath the sheathing amongst the rafter bays."

Just because a roof assembly doesn't Keep to the procedures set up through the making code or recommendations of creating researchers doesn't mean the roof has

Q. "If I put in a polyethlene sheet amongst the bottom in the batting and the sheetrock [it would be hooked up to the purlins], wouldn't this be an interior vapor barrier?"

Magic bullet standing is not accomplished. It is a design for your lower slope roof. It truly is a great deal along the traces of Doug McEvers utilization of high perm fibre board to generate vent channels higher than dense packed cellulose.

an air barrier. If you want to install EnGard insulation batts within an unvented cathedral ceiling, You will need to own a major layer of rigid foam insulation earlier mentioned the roof sheathing.

Make sure you install insulation that supplies at least the bare minimum code need for ceiling R-worth. Insulation that exceeds the least code prerequisite is better still.

Re: the air barrier to get positioned above the pine T&G ceiling and below the foam, would you propose that we use anything that is both equally an air barrier and a vapor barrier? Or can it be important to verify that the product or service we choose is NOT a vapor barrier, so that any dampness that will get to the roof assembly can dry to The within?

In order to put in a combination of closed-cell spray-foam over the underside from the roof sheathing and air-permeable insulation amongst your rafters — an tactic at times identified as “flash and batt” — check my blog the developing code calls for that spray foam (or, arguably, rigid foam insulation) be “utilized in direct Speak to with the underside from the structural roof sheathing” and that the foam insulation fulfill the necessities “specified in Table R806.

In order to develop an unvented insulated roof assembly, you have got two selections: (a) You can increase rigid foam to the exterior aspect of your roof sheathing, followed by a 2nd layer of roof sheathing and new roofing, or (b) You'll be able to insulate the underside within your roof sheathing with spray polyurethane foam.

Yesterday we blew the insulation and put in the SIGA Majcoat within the CAPACES Management Institute. There was much more than eight,000 Cubic ft of insulation to set up, so our insulators experienced two of their blower trucks and a good crew on site. They were being blowing cellulose as fast as they might as well as the the rain was heading our direction. Fewer than forty five minutes once the insulation was done we had concluded the Majcoat and ended up chaotic taping seams.

A. To make the most of the insulating value of the rigid foam around the attic, you undoubtedly would like to seal up any attic vents, and you simply my sources unquestionably don't want to make a ridge vent.

Install shut-mobile spray read the full info here foam in opposition to the underside from the roof sheathing, and no other style of insulation. Make sure that the thickness of the spray foam is satisfactory to satisfy minimum amount code needs. Recall that open up-cell spray foam is dangerous in all weather zones, and if open up-cell spray foam is set up With this location in a chilly weather, the underside in the cured foam should be coated with gypsum drywall that has become painted with vapor-retarder paint. Vapor-retarder paint is ineffective if it is sprayed directly to the cured foam.

The edges in the roof are protected with asphalt shingled (GAF Slateline being specific). It seems like I really should pull down the fiberglass and also have it spray-foamed ahead of I drywall.